    Product Description

    Product Details:

    Parameters ECG
    Parameters Measured ECG, RESP, NIBP, SPO2, Temperature, IBP, PR
    Type of display LCD
    Display Size 12 INCH
    Suitable For Adult, Pediatric, Neonatal
    Brand TECHNOCARE MEDISYSTEMS
    Model TM-9009P


    We are offering high quality "Multi Parameter Monitor" 12 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, TEMP, PR / HR
    Technical specification:


    ECG:

     

    Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2 ch Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection: I, II, III, Waveform: 1 chGain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

    HR and Alarm:

     

    Range Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm Accuracy : ± 1% or ± 1bpm, which great Resolution: 1 bpm Sensitivity: > 200 (uV P-P)

     

    • Differential Input Impedance: > 5 MΩ
    • Monitor: > 105 dB
    • Operation: > 105 dB
    • Diagnosis: > 85 dB
    • Electrode offset potential: ±300mV
    • Leakage Current: < 10 uA
    • Baseline Recovery: < 3 S After Defi.
    • ECG Signal Range: ±8 m V ( Vp-p )
    • Surgery: 1 ~ 15 Hz
    • Monitor: 0.5 ~ 35 Hz
    • Diagnostic: 0.05 ~ 100 Hz
    • Calibration Signal: 1 (mV p-p), Accuracy:±5%
    • ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
    • ARR Detecting
    • Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,

    Resparation:

    • Method: Impedance between R-F (RA-LL)
    • Differential Input Impedance: >2.5 MΩ
    • Measuring Impedance Range: 0.3~5.0Ω
    • Base line Impedance Range: 0 – 2.5 KΩ
    • Bandwidth: 0.3 ~ 2.5 Hz
    • Resp. Rate
    • Measuring and Alarm Range
    • Adult: 0 ~ 120 rpm
    • Neo/Ped: 0 ~ 150 rpm
    • Resolution: 1 rpm
    • Accuracy : ±2 rpm
    • Apean Alarm: 10 ~ 40 S


    NIBP:

    • Method: Oscillometric
    • Mode: Manual, Auto, STAT
    • Measuring Period in STAT Mode: 5 Min
    • Pulse Rate Range: 40 ~ 240 bpm
    • Alarm Type: SYS, DIA, MEAN
    • Measuring and alarm range
    • SYS: 40 ~ 270 mmHg
    • DIA: 10 ~ 215 mmHg
    • MEAN: 20 ~ 235 mmHg
    • Pediatric Mode
    • SYS: 40 ~ 200 mmHg
    • DIA: 10 ~ 150 mmHg
    • MEAN:20 ~ 165 mmHg
    • Neonatal Mode
    • SYS: 40 ~ 135 mmHg
    • DIA:10 ~ 100 mmHg
    • MEAN:20 ~ 110 mmHg
    • Resolution Pressure:1mmHg
    • Accuracy Pressure Maximum Mean error: ±5mmHg
    • Maximum Standard deviation: ±8mmHg
    • Adult Mode: 297±3 mmHg
    • Pediatric Mode: 240±3 mmHg
    • Neonatal Mode: 147±3 mmHg

    SpO2:
    • Measuring Range: 0 ~ 100 %
    • Alarm Range: 0 ~ 100
    • Resolution: 1 %
    • Accuracy : 70% ~ 100% ±2 %, 0% ~ 69% unspecified
    • Actualization interval: about 1 Sec.
    • Alarm Delay: 10 Sec.


    Pulse Rate:

    • Measuring and Alarm Range: 20~300bpm
    • Resolution: 1bpm
    • Accuracy : ±2bpm


    Temperature:

    • Channel: 2
    • Measuring and Alarm Range: 0 ~ 50 °C
    • Resolution: 0.1°C
    • Accuracy : ±0.1°C
    • Actualization interval: about 1 Sec.
    • Average Time Constant:<10 Sec.