Most Popular Products
ST30 Topson Bipap
ST30 Topson Bipap Specification
- Treatment Type
- Dual airway pressure support
- Height
- 10 cm
- Application
- Hospital
- Power
- 60 W
- Humidity Range
- 0 to 80% RH
- Product Type
- ST30 Topson Bipap
- Temperature Range
- 5°C to 35°C
- Shape
- Rectangular
- Accuracy
- ±2 cmH2O
- Material
- Plastic
- Weight
- 1.8 kg
- Storage Capacity
- Data storage up to 365 days
- Suitable For
- Adult & Pediatric Patients
- Frequency
- 50/60 Hz
- Function
- Non-invasive positive pressure ventilation
- Properties
- S/T BiPAP mode, Non-invasive ventilation
- Color Code
- White
- Phase
- Single Phase
- Display Type
- Digital
- Dimension (L*W*H)
- 32 x 20 x 10 cm
- Automation Grade
- Automatic
- Use
- Hospital
- Power Source
- AC Power
- Display
- LCD Display
- Voltage
- 220-240 V
- Alarm Functions
- Leak, Apnea, Low/High Pressure, Power Failure
- Inspiratory Time
- 0.5-3.0 sec
- Language Support
- Multi-language
- Ramp Time
- 0 to 45 min
- Sound Level
- <30 dB
- Backup Rate
- 4-40 bpm
- Data Interface
- SD Card, USB
- Mask Type
- Compatible with full-face and nasal masks
- Accessories Included
- Tubing, Humidifier, Filter, Power Cord, Mask
- Pressure Range
- 4 to 30 cmH2O
- Operating Altitude
- 0-2500 m
- Compliance Monitoring
- Yes
- Modes Supported
- S, T, ST, CPAP
ST30 Topson Bipap About
For patients with respiratory disorders or sleep apnoea, the state-of-the-art ST30 Topson BiPAP ventilator offers efficient respiratory support. With its cutting-edge BiPAP technology, it helps with breathing by lowering airway resistance and improving oxygenation by delivering both inspiratory and expiratory pressure. For added comfort, the gadget has an inbuilt humidifier, user-friendly interface, and customisable pressure settings. Easy portability and convenient use at home or in clinical settings are guaranteed by its small size. By providing the best possible respiratory support, the ST30 Topson BiPAP's quiet operation and dependable performance enhance patient outcomes.
Advanced Ventilation Modes
With S, T, ST, and CPAP modes, the ST30 Topson BiPAP caters to diverse respiratory needs, providing both spontaneous and timed ventilation support. This flexibility benefits adult and pediatric patients alike, adapting to specific clinical demands within hospital settings.
Comprehensive Safety and Monitoring
Equipped with alarms for leaks, apnea, and pressure irregularities, plus power failure alerts, the device ensures patient safety. Its compliance monitoring system and long-term data storage help medical professionals track therapy effectiveness over time.
Designed for Comfort and Usability
Offering ultra-quiet performance below 30 dB and an intuitive digital LCD display, the ST30 enhances patient comfort and ease of operation. The included humidifier and mask options further support individualized, comfortable treatment for inpatients and outpatients.
FAQ's of ST30 Topson Bipap:
Q: How do I use the ST30 Topson BiPAP for both adult and pediatric patients?
A: The ST30 Topson BiPAP features adjustable modes and pressure ranges suitable for adults and children. Select the appropriate mask type, customize pressure, ramp time, and backup rate according to the clinical need, then monitor patient status via the digital LCD display.Q: What are the primary benefits of the automated alarm functions?
A: The ST30 integrates alarm systems for leaks, apnea, pressure deviations, and power failures. These alarms promptly notify caregivers of potential issues, ensuring timely intervention and maximizing patient safety during therapy.Q: When should I change or clean the device's accessories, such as the filter and tubing?
A: It's recommended to inspect and clean the mask, tubing, and filter weekly or as per hospital infection control protocols. Regular maintenance supports device longevity and minimizes infection risks.Q: Where is patient usage data stored, and how can it be accessed?
A: All therapy data is securely stored on an SD card or can be transferred via USB. Medical staff can retrieve and review up to 365 days of treatment information for assessment or compliance reporting.Q: What makes the ST30 Topson BiPAP suitable for Indian hospital environments?
A: Engineered for operational reliability under varying altitudes (up to 2500 m) and temperatures (5C to 35C), the ST30 is compatible with local voltage, has multilingual support, and meets the practical needs of healthcare providers across India.Q: How does the ramp feature enhance patient comfort during therapy?
A: The adjustable ramp time (0-45 min) allows the device to gradually increase airway pressure, giving patients a gentle and comfortable transition to their prescribed therapeutic pressure level.
Tell us about your requirement
Price:
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+