        Portable Anesthesia Flowmeter

        Portable Anesthesia Flowmeter
        Portable Anesthesia Flowmeter

        Portable Anesthesia Flowmeter Specification

        • Technology
        • Mechanical with Precision Control Valves
        • Power
        • Not Required (Manual Operation)
        • Suitable For Use
        • Hospitals, Ambulance, Clinics
        • Equipment Type
        • Portable Anesthesia Flowmeter
        • Capacity
        • Up to 10 L/min (Oxygen and Nitrous Oxide)
        • Application
        • Operating Rooms, Emergency Ambulance, Field Hospitals
        • Size
        • Standard Compact
        • Operating Type
        • Manual
        • Storage Instructions
        • Store in Cool, Dry Place Away from Direct Sunlight
        • Noise Level
        • < 40 dB
        • Portable
        • Yes
        • Color
        • White with Blue and Silver Accents
        • Set Contains
        • Flowmeter Unit, Oxygen & N2O Flowmeters, Tubing Connectors
        • Dimension (L*W*H)
        • Approx. 38 cm x 14 cm x 12 cm
        • Shape
        • Rectangular Base with Cylindrical Flow Tubes
        • Accuracy
        • ± 5% of Full Scale
        • Real-Time Operation
        • Yes
        • Operation Mode
        • Manual
        • Wall Mounted
        • No
        • Feature
        • Portable, Corrosion-Resistant, Easy to Use
        • Condition
        • New
        • Function
        • Measures and Regulates Oxygen/Nitrous Oxide Flow
        • Use
        • Regulating and Monitoring Medical Gases during Anesthesia Procedures
        • Attributes
        • Flow Adjustment, Leak-Proof Design, Lightweight
        • Material
        • Aluminum Alloy, Stainless Steel, Medical-grade Polycarbonate
        • Number of Tubes
        • 2 (for Oxygen and Nitrous Oxide)
        • Safety Features
        • Anti-Leakage Valve, Pressure Relief Mechanism
        • Mounting Options
        • Portable/Tabletop
        • Outlet Connection
        • Quick Connect Fittings
        • Inlet Pressure
        • 4.5 Bar (Oxygen, Nitrous Oxide)
        • Cleaning Instructions
        • Wipe with Medical Disinfectant
        • Flowmeter Range
        • O2: 0.1-10 L/min, N2O: 0.1-8 L/min
        • Scale Type
        • Clear, Engraved, Easy-to-Read Graduation Marks
         
         

        Portable Anesthesia Flowmeter About

        A small, lightweight tool for accurate medical gas delivery in clinics, emergency scenarios and field settings is the Portable Anesthesia Flowmeter. Accurate gas mixing and flow rate adjustment are made possible by its dual flow control for nitrous oxide and oxygen. Its long-lasting, corrosion-resistant construction guarantees dependability and steady performance in a range of circumstances. Operational safety is improved by the user-friendly interface with distinct flow indicators. This flowmeter is a crucial instrument for the safe and efficient administration of anaesthesia while on the road because it is portable without sacrificing accuracy or durability, making it perfect for mobile medical units and veterinary applications.


        Reliable Gas Flow Measurement and Regulation

        This flowmeter is engineered for accuracy and dependability, featuring clear, engraved graduation marks and precision control valves for real-time adjustments. Medical practitioners can confidently measure and regulate both oxygen and nitrous oxide flows simultaneously, ensuring patient safety throughout anesthesia procedures.


        Built for Versatility and Portability

        With a lightweight, compact design optimized for portability, this anesthesia flowmeter is ideal for various setups including portable and tabletop placement. Its corrosion-resistant materials and manual operation make it a robust choice for use in operating rooms, emergency ambulances, and field hospitals.


        Safety, Hygiene, and Ease of Use

        Safety is emphasized with anti-leakage valves and pressure relief mechanisms. Clear scale visibility and leak-proof design further enhance operational confidence. For hygiene, simply wipe the unit with a medical disinfectant after each use. No power supply is necessary, simplifying operation and maintenance.

        FAQ's of Portable Anesthesia Flowmeter:


        Q: How do I install and set up the Portable Anesthesia Flowmeter?

        A: Installation is straightforward-mount the unit on a flat surface or tabletop using the base, connect the quick connect fittings to the gas sources, and attach tubing as needed. Ensure inlet pressures for oxygen and nitrous oxide are at 4.5 bar for proper operation.

        Q: What maintenance or cleaning procedures should be followed?

        A: To maintain hygiene and functionality, wipe the flowmeter's surfaces with a medical disinfectant after each use. Avoid immersion in liquids. Store in a cool, dry place away from direct sunlight to extend its service life.

        Q: When is this flowmeter most beneficial?

        A: This device is especially valuable in operating rooms, ambulances, clinics, and field hospitals where precision gas monitoring is critical and portability is essential. Its manual operation ensures uninterrupted use during power outages or in mobile situations.

        Q: Where can this flowmeter be used?

        A: The unit is suitable for use in diverse healthcare environments such as hospitals, ambulances, emergency field hospitals, and clinics. Its portable design allows it to be easily transferred between locations as needed.

        Q: What gases and flow rates are supported by this device?

        A: The flowmeter regulates and measures both oxygen (O2) from 0.1 to 10 L/min and nitrous oxide (N2O) from 0.1 to 8 L/min, providing accurate delivery for a wide range of anesthesia procedures.

        Q: How does the device ensure safety during medical procedures?

        A: Safety mechanisms include an anti-leakage valve that minimizes gas leaks and a pressure relief feature to help prevent overpressurization. The clear, engraved graduation marks enable precise flow adjustment, supporting safe administration.

        Q: What benefits does its manual operation offer?

        A: Manual operation means the device functions independently of electrical power, providing reliable operation in all environments. It enables real-time adjustments for flow rates and contributes to the overall ease of use and portability.