Anaesthesia Multigas Sidestrem Analyzer Specification
- Accuracy
- CO2: 2 mmHg, O2: 2%, N2O: 2%
- Set Contains
- Analyzer, Sampling Line, User Manual
- Dimension (L*W*H)
- 245 x 165 x 110 mm
- Color
- White & Grey
- Operation Mode
- Manual / Automatic
- Application
- Operation Theatres, ICUs
- Size
- Standard / Compact
- Condition
- New
- Power Consumption
- <35W
- Material
- ABS & Medical Grade Plastics
- Use
- Monitoring Gas Concentrations during Anaesthesia
- Attributes
- Auto Calibration, Multi-Gas Detection, Digital Display
- Power
- AC 100-240V, 50/60Hz
- Storage Instructions
- Store in Dry, Cool Environment
- Technology
- Infrared Spectroscopy
- Function
- Multi-Gas Analysis (CO2, O2, N2O, Anaesthetic Agents)
- Voltage
- 100-240V AC
- Capacity
- Continuous Sampling
- Feature
- Compact Design, Alarm System, Real-Time Digital Display
- Real-Time Operation
- Yes
- Wall Mounted
- No
- Portable
- Yes
- Operating Type
- Electronic
- Suitable For Use
- Anaesthesia Workstations
- Lighting Type
- Display Backlight
- Noise Level
- <40 dB
- Equipment Type
- Anaesthesia Multigas Sidestream Analyzer
- Shape
- Rectangular
- Sample Line Length
- 2 m (standard, customizable)
- Sample Flow Rate
- 150250 ml/min
- Measuring Range (Anesthetic Agent)
- 08 vol%
- Measuring Range (O2)
- 0100%
- Data Output
- RS232, USB
- Operating Temperature
- 10C 40C
- Compliance
- IEC 60601-1; CE Marked
- Relative Humidity
- 15%90% (non-condensing)
- Calibration
- Automatic and Manual
- Weight
- Approx. 2.6 kg
- Alarm Types
- Visual and Audible (High/Low Gas Levels, Sample Line Occlusion, Power Failure)
- Service Life
- 5 years or more
- Warm-Up Time
- <5 minutes
- Display Type
- High-Resolution LCD
- Measuring Range (CO2)
- 015% (0113 mmHg)
- Measuring Range (N2O)
- 0100%
About Anaesthesia Multigas Sidestrem Analyzer
The Anaesthesia Multigas Sidestream Analyzer is a compact, high-precision device designed to monitor respiratory gases during anesthesia. It accurately measures concentrations of oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), and volatile anesthetic agents like Isoflurane and Sevoflurane. Using sidestream technology, it continuously samples gas from the breathing circuit without interfering with ventilation. Its intuitive interface, fast response time, and real-time waveform display enhance patient safety and clinical decision-making. Lightweight and easy to integrate with existing monitors, this analyzer is ideal for operating rooms, ICUs, and mobile medical setups requiring reliable, continuous gas monitoring.
Real-Time Multi-Gas Detection and Analysis
Benefit from simultaneous, continuous monitoring of CO2, O2, N2O, and anesthetic agents using advanced infrared spectroscopy. The analyzer supports both manual and automatic operation, ensuring precise, real-time data for improved patient safety during anaesthesia procedures. Its robust sample flow rate and automated calibration maintain consistent, reliable performance.
User-Friendly Design and Alarm System
The high-resolution LCD offers clear digital display of gas concentrations, while intuitive visual and audible alarms immediately alert you to high or low gas levels, occlusions, or power interruptions. Lightweight, portable, and constructed from medical-grade materials, it is designed for ease of use in demanding clinical environments.
Versatile Connectivity and Compliance
With RS232 and USB data output, the analyzer easily integrates into modern hospital information systems. Its adherence to IEC 60601-1 standards and CE certification ensures the highest safety and quality for use in OT and ICU settings. The sample line length is customizable, and its compact size makes it suitable for various clinical applications.
FAQ's of Anaesthesia Multigas Sidestrem Analyzer:
Q: How does the Anaesthesia Multigas Sidestream Analyzer measure gas concentrations?
A: The analyzer uses infrared spectroscopy technology to detect and quantify gas concentrations-CO2, O2, N2O, and anesthetic agents-in exhaled air samples. It draws samples through a sidestream line and continuously measures their levels in real-time, displaying results instantly on the LCD screen.Q: What is the process for calibrating the analyzer?
A: Calibration can be performed automatically by the device at set intervals, or manually by the user as needed. The process ensures ongoing accuracy in gas measurement and can be initiated through the user interface following the instructions in the user manual provided.Q: When should the alarm system be expected to activate?
A: The alarm system provides both visual and audible notifications whenever gas concentrations exceed preset high or low thresholds, if a sample line occlusion occurs, or during a power failure. This immediate feedback supports a safer anaesthesia environment.Q: Where can this analyzer be used most effectively?
A: The device is ideal for use in operation theatres (OTs), intensive care units (ICUs), and anaesthesia workstations. Its compact and portable design makes it adaptable for any clinical setting needing continuous multi-gas monitoring during anaesthesia.Q: What are the key benefits of using this analyzer in clinical practice?
A: Key benefits include accurate, real-time monitoring of multiple gases, robust alarm functions for patient safety, easy integration with data systems via RS232/USB, and compliance with medical standards such as IEC 60601-1 and CE. Its durable, portable design supports prolonged, dependable use.Q: How should the analyzer be stored when not in use?
A: Store the analyzer in a dry, cool environment to maintain optimal performance and longevity. Ensure it is kept away from moisture and extreme temperatures, in accordance with the storage instructions provided.
Tell us about your requirement
Price:
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+
Additional detail
Mobile number
Email
![]() |
TECHNOCARE MEDISYSTEMS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |